93
93EN
MANUAL ELDES ESIM264 V3.1
30. MONITORING STATION
The system can be congured to report events to the monitoring station by transmitting data messages to the monitoring station. The
system connects to the monitoring station when the MS (Monitoring Station) mode is enabled.
Enable MS mode
SMS
SMS text message content:
ssss_SCNSET:ON
Value: ssss – 4-digit SMS password.
Example: 1111_SCNSET:ON
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → MS SETTINGS → OK → MS MODE → OK →
ENABLE → OK
Value: aaaa – 4-digit administrator password
EKB3
Enter parameter 23 & parameter status value:
23 1 #
Example: 231#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Disable MS mode
SMS
SMS text message content:
ssss_SCNSET:OFF
Value: ssss – 4-digit SMS password.
Example: 1111_SCNSET:OFF
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → MS SETTINGS → OK → MS MODE → OK →
DISABLE → OK
Value: aaaa – 4-digit administrator password
EKB3
Enter parameter 23 & parameter status value:
23 0 #
Example: 230#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Account is a 4-digit number (By default – 9999) required to identify the alarm system unit by the monitoring station.
Set account
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → MS SETTINGS → OK → ACCOUNT → OK → cccc
→ OK
Value: aaaa – 4-digit administrator password; cccc – 4-digit account number.
EKB3
Enter parameter 27 & account number:
27 cccc #
Value: cccc – 4-digit account number.
Example: 278853#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
ATTENTION: The system will NOT send any data to the monitoring station while remote conguration, remote rmware update or remote
listening/2-way voice communication is in progress. However, during the remote conguration session, rmware update process or remote
listening/2-way voice communication process, the data messages will be queued up and transmitted to the monitoring station after the
remote conguration session, rmware update or remote listening/2-way voice communication process is over.
ATTENTION: Phone calls to the preset user phone number in case of alarm are disabled by force when MS mode is enabled.