137
137EN
MANUAL ELDES ESIM264 V3.1
ATTENTION: The minimum wireless connection range between the wireless device and wireless antenna of ESIM264 system can be
0,5 meters.
32.6.3. EWS1 Zone, PGM Output & Tamper
Upon successful EWS1 indoor siren binding process,the system adds 1 wireless Instant zone and 1 wireless Siren PGM output. The wireless
zone is intended for EWS1 tamper control and the wireless PGM output is for siren control.
In case of tamper violation, the alarm is caused regardless of system being armed or disarmed. The wireless connection loss between EWS1
and ESIM264 system leads to alarm. The system identies this event as a tamper violation and sends alarm by SMS text message and phone
call to the user (-s) by default. The SMS text message contains the violated tamper number and a star * character indicating wireless connec-
tion loss as a tamper alarm cause.
ATTENTION: The tamper will not operate if the wireless zone is disabled.
32.6.4. Battery Replacement
1. Open EWS1 enclosure.
2. Remove all 3 old batteries from the battery slots.
3. Postition the 3 new 1,5V alkaline AA type batteries according to the appropriate battery slot positive/negative terminals indicated on the
PCB (printed-circuit-board) of EWS1
4. Insert the batteries into the battery slots.
5. Batteries replaced.
For more details, please refer to 32.6.2 Installation.
ATTENTION: Only CR2032 3V batteries can be used. Install only new, high quality and unexpired batteries. Do not mix the old batteries
with the new ones.
ATTENTION: At least 1 battery must be removed if the device is not in use.
ATTENTION: In order to avoid re or explosion hazards, the system must be used only with approved battery. Special care must be
taken when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge,
disassemble, heat or incinerate old batteries.
NOTE: The battery status can be monitored in real-time using ELDES Conguration Tool software.
32.6.5. Restoring Default Parameters
1. Remove any battery from EWS1.
2. Press and hold the RESET button.
3. Insert the battery back to EWS1.
4. Hold the RESET button until LED indicator provides several short ashes.
5. Release the RESET button.
6. Parameters restored to default.
32.7. EWS2 – Wireless Outdoor Siren
Main EWS2 features:
• Audio alarm indication by built-in speaker;
• Visual alarm indication by built-in LED indicators;
• Range of operating temperature: -30...+55
o
C.
EWS2 is a wireless outdoor device with a built-in siren speaker, LED indicators and operates with ELDES wireless alarm systems. EWS2 has to
be bind to the alarm system by sending a corresponding SMS text message or using software ELDES Conguration Tool. Upon successful EWS2
binding process, the system adds one wireless zone and one wireless PGM output. In case of alarm, the siren provides a sound alarm for one
minute. The conguration of this parameter is disabled for EWS2 in order to save the battery power.
It is possible to connect up to 16 EWS2 devices to the alarm system at a time. The maximum wireless connection range is 150 meters (in open
areas).