Set zone connection
type for 6-Zone mode
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK ZONES OK ZONE TYPE:6-ZONE M
OK TYPE 1... 3 OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 39 & number of zone connection type:
39 1 # – Type 1
39 2 # – Type 2
39 3 # – Type 3
Example: 392#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
14.4. ATZ (Advanced Technology Zone) Mode
The ATZ mode is a software-based feature that doubles the number of on-board zones and enables two detection devices to be installed
per 1 zone terminal. Once this mode is enabled, the zone connection Type 4 is set automatically. The detection devices must be wired to
the on-board zone terminals as indicated in the wiring diagram of the associated zone connection type. Available zone connection types
for the ATZ mode:
Type 4 – Parallel wiring of 2 NC (normally-closed) detection devices with 5,6k and 3,3k EOL (end-of-line) resistors respectively.
5,6k EOL resistor corresponds to zones ranging from Z1 through Z6, while 3,3k EOL resistor corresponds to zones ranging from Z7
through Z12.
Type 5 – Combination of serial and parallel wiring of tamper with 5,6k EOL resistor and 2 NC (normally-closed) detection devices with
5,6k and 3,3k EOL resistors respectively. 5,6k EOL resistor corresponds to zones ranging from Z1 through Z6, while 3,3k EOL
resistor corresponds to zones ranging from Z7 through Z12.
For zone wiring diagrams of the ATZ mode, please refer to 2.3.2. Zone Connection Types.
Enable ATZ mode
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK ZONES OK ATZ MODE OK
ENABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 28 & parameter status value:
28 1 #
Example: 281#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Disable ATZ mode
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK ZONES OK ATZ MODE OK
DISABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 28 & parameter status value:
28 0 #
Example: 280#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.