121
121EN
MANUAL ELDES ESIM264 V3.1
31.2. 1-Wire Interface
1-Wire interface is used for the system to communicate with an iButton key reader and up to 8 temperature sensors. 1-Wire interface COM and
DATA terminals are ground and data respectively. When connecting single or multiple temperature sensors, the +5V terminal must be used along.
For more details on 1-Wire device wiring, please refer to 32.2.1 iButton Key Reader and Buzzer
31.2.1. iButton Key Reader and Keys
The iButton key is a microchip enclosed in a stainless steel tab usually implemented in a small plastic holder. Each iButton key holds a
unique 64-bit identity code (ID), which is used for alarm system ESIM264 arming and disarming procedure.
Main iButton features:
• Up to 5 iButton keys per alarm system unit ESIM264;
• Communication via 1-Wire interface.
31.2.1.1. Technical Specications
31.2.1.1.1 Electrical & Mechanical Characteristics
Supported iButton Key Model Maxim/Dallas DS1990A
Communication Interface 1-Wire
Maximum Cable Length for 1-Wire Communication up to 30 meters
31.2.1.1.2 Installation
1. Disconnect ESIM264 alarm system main power supply and backup battery.
2. Connect iButton key reader contact wires to 1-Wire interface on ESIM264 alarm system: COM and DATA terminals respectively.
COM
DATA
iButton
key reader
49
3. Power up ESIM264 alarm system.
4 iButton key reader is ready for use with ESIM264 alarm system.
For more details on iButton key management, please refer to 11. iBUTTON KEYS.
31.3. Modules Interface
31.3.1. EPGM8 - Hardwired PGM Output Expansion Module
EPGM8 is a PGM output expansion module intended for using with alarm system ESIM264. This module allows to connect up to additional
8 electrical appliances.
Main EPGM8 features:
• PGM output expansion adding 8 additional PGM outputs;
• Compatible with ESIM264 alarm system
Kommentare zu diesen Handbüchern