78 EN
MANUAL ELDES ESIM264 V3.1
23. PARTITIONS
ESIM264 system comes equipped with a partitioning feature that can divide the alarm system into two independently controlled areas
identied as Partition 0 through 1, which are all supervised by one alarm system unit. Partitioning can be used in installations where shared
alarm system is more practical, such as a house and a garage or within a single multi-storey building. When partitioned, each system ele-
ment, like zone, user phone number, keypad, user password, iButton key and wireless keyfob can be assigned to one of the partitions. The
user will then be able to arm/disarm the system partition that the zones and arm/disarm method are assigned to.
23.1. Zone Partition
Zone partition determines which system partition (-s) the zone will operate in.
Set zone partition
EKB2
Menu path:
On-board zone: OK CONFIGURATION OK aaaa OK ZONES OK ONBOARD
ZONES OK ZONE 1... 12 OK PARTITION OK PARTITION0... 1 OK
Wireless zone: OK CONFIGURATION OK aaaa OK ZONES OK WIRELESS
ZONES OK WLESS ZONE 1... 16 OK PARTITION OK PARTITION0... 1 OK
Keypad zone: OK CONFIGURATION OK aaaa OK ZONES OK KEYPAD
ZONES OK KEYPAD 1... 4 ZONE OK PARTITION OK PARTITION0... 1 OK
EPGM1 zone: OK CONFIGURATION OK aaaa OK ZONES OK EPGM1 ZONES
OK EPGM1 ZONE 1... 16 OK PARTITION OK PARTITION0... 1 OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 57, zone number & partition value:
57 nn p #
Value: nn – zone number, range – [01... 44]; p – partition number, range – [0... 1].
Example: 57031#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
23.2. User Phone Number Partition
User phone number partition determines which system partition (-s) can be armed/disarmed from a certain user phone number by dialing
system’s phone number.
Set user phone
number partition
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETTINGS OK CALL/SMS
SETTINGS OK USERS OK USER 1... 5 OK PARTITION OK PARTITION0... 1
OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 59, user phone number slot & partition number:
59 us p #
Value: nn – zone number, range – [01... 44]; p – partition number, range – [0... 1].
Example: 59030#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.