4. Insert the PCB back to the enclosure and close it.
5. Bind the device to the alarm system by sending a corresponding command via SMS text message or using ELDES Conguration Tool
soft ware. Please, refer to the software‘s HELP section or refer to 19.1. Binding, Removing and Replacing Wireless Devices for
more details.
6. While binding the device to the alarm system, press any EWK2 button several times.
7. EWK2 is ready for use.
NOTE: If you are unable to bind the wireless device, please, restore the parameters of the wireless device to default and try again. See
chapter 32.10.5. Restoring Default Parameters for more details.
32.10.3. EWK2 Zones (Panic Button)
EWK2 keyfob supports a Panic Button feature allowing to cause alarm at any time when the specied button is pressed. This feature can
be congured using ELDES Conguration Tool by creating a virtual zone of Panic/Silent or 24-Hour type and assigning it to Virtual Alarm
option. The Panic Button feature can be set up on any button of EWK2.
32.10.4. Battery Replacement
1. Open EWK2 enclosure.
2. Remove the old battery from the battery slot.
3. Postition the new battery according to the appropriate battery slot positive terminal indicated.
4. Insert the battery into the battery slot.
5. Battery replaced.
See 32.10.2. Installation for more details.
ATTENTION: Only CR2032 3V battery can be used. Install only new, high quality and unexpired batteries.
ATTENTION: The battery must be removed if the device is not in use.
ATTENTION: In order to avoid re or explosion hazards, the system must be used only with approved battery. Special care must be
taken when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge,
disassemble, heat or incinerate old batteries.
NOTE: The system sends an SMS message to a preset User 1 as soon as the battery level runs below 5%.
NOTE: The battery status can be monitored in real-time using ELDES Conguration Tool software.
32.10.5. Restoring Default Parameters
1. Press and hold and buttons simultaneously.
2. Hold the buttons pressed until LED indicator and the buzzer provide several short ashes and beeps simultaneously.
3. Release the buttons.
4. Parameters restored to default.