82
82 EN
MANUAL ELDES ESIM264 V3.1
View MIN and
MAX temperature
boundaries
SMS
SMS text message content:
ssss_TEMP
Value: ssss – 4-digit SMS password.
Example: 1111_TEMP
EKB2
Menu path:
MIN: OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETTINGS → OK →
TEMPERATURE SENSOR → OK → TEMP. MIN
MAX: OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETTINGS → OK →
TEMPERATURE SENSOR → OK → TEMP. MAX
Value: aaaa – 4-digit administrator password.
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
By default, Temperature Info SMS is enabled. To disable/enable it, please refer to the following conguration methods.
Disable Temperature
Info SMS
SMS
SMS text message content:
ssss_TEMP:00:00
Value: ssss – 4-digit SMS password.
Example: 1111_TEMP:00:00
EKB2
Menu path:
Temperature fallen: OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK →
TEMP LOW EVENT → OK → DISABLE → OK
Temperature exceeded: OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK
→ TEMP HIGH EVENT → OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 24, event number & parameter status value:
25 14 0 # - Temperature fallen
25 15 0 # - Temperature exceeded
Example: 25140#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Enable Temperature
Info SMS
EKB2
Menu path:
Temperature fallen: OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK →
TEMP LOW EVENT → OK → ENABLE → OK
Temperature exceeded: OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK
→ TEMP HIGH EVENT → OK → ENABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 24, event number & parameter status value:
25 14 1 # - Temperature fallen
25 15 1 # - Temperature exceeded
Example: 25151#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.