122 EN
MANUAL ELDES ESIM264 V3.1
31.3.1.1. Technical Specications
31.3.1.1.1 Electrical & Mechanical Characteristics
Power Supply 10-24V 100mA max
Number of PGM Outputs 8
EPGM8 PGM Output Circuit
1 R
OUT
Open collector output.
Output is pulled to COM
when turned on.
Maximum Commuting PGM Output Values Voltage – 30V; current 500mA
Dimensions 40 x 55 x 15 mm
Humidity
0-90% RH @ 0... +40 °C (non-condensing)
Range of Operating Temperatures -20...+55ºC
31.3.1.1.2 Connector Functionality
D1 - D8 PGM output terminals
12V Positive power supply terminal
GND Negative power supply terminal
D1 D2 D3 D4 D5 D6 D7 D8
12V GND
50
31.3.1.2. Installation
1. Disconnect ESIM264 alarm system main power supply and backup battery.
2. Insert EPGM8 pins into appropriate ESIM264 alarm system slots (see Fig. No. 51)
D1 D2 D3 D4 D5 D6 D7 D8
12V GND
EPGM8
ESIM264
51