MANUAL ELDES ESIM264 V3.1
22. GSM CONNECTION STATUS MONITORING
The system constantly supervises the GSM connection. When the GSM signal is lost, the system indicator NETW will light OFF, the keypad
will indicate system fault condition (see 29. INDICATION OF SYSTEM FAULTS) and the system will turn ON a determined PGM output if
the GSM signal is lost for a longer time period than the set delay value (By default – 180 seconds). Once the GSM signal restores, the keypad
will no longer indicate system fault and the determined PGM output will turn OFF.
By default, the PGM output for GSM signal loss indication is not set. To set the PGM output and delay duration for GSM signal loss indication,
please refer to the following conguration method.
Manage GSM signal
loss indication by PGM
output
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Seitenansicht 76