Seitenansicht 71
72
72 EN
MANUAL ELDES ESIM264 V3.1
20.1. Bell Squawk
If enabled, the siren/bell indicates the completed system arming and disarming process. After the system is successfully armed, the siren/
bell will emit 2 short beeps and 1 long beep after the system is disarmed. To enable/disable the Bell Squawk feature, please refer to the
following conguration methods.
Enable Bell Squawk
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETT INGS OK SIREN SETTINGS
OK BELL SQUAWK OK ENABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 29 & parameter status value:
29 1 #
Example: 291#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Disable Bell Squawk
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETT INGS OK SIREN SETTINGS
OK BELL SQUAWK OK DISABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 29 & parameter statusvalue:
29 0 #
Example: 290#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
20.2. Indication by EWS2 Indicators
When enabled, the built-in LED indicators of EWS2 wireless outdoor siren will ash during the alarm. To enable/disable this feature, please
refer to the following conguration methods.
Enable EWS2 LED
indication
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETT INGS OK SIREN SETTINGS
OK EWS2 LED OK ENABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 29 & parameter status value:
88 1 #
Example: 881#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.