103
103EN
MANUAL ELDES ESIM264 V3.1
Set APN
SMS
SMS text message content:
ssss_SETGPRS:APN:acc-point-name
Value: ssss – 4-digit SMS password; acc-point-name – up to 31 character APN (Access Point
Name) provided by the GSM operator.
Example: 1111_SETGPRS:APN:internet
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Set user name
SMS
SMS text message content:
ssss_SETGPRS:USER:usr-name
Value: ssss – 4-digit SMS password; usr-name – up to 31 character user name provided by
the GSM operator.
Example: 1111_USER:mobileusr
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Set password
SMS
SMS text message content:
ssss_SETGPRS:PSW:password
Value: ssss – 4-digit SMS password; password – up to 31 character password provided by
the GSM operator.
Example: 1111_SETGPRS:PSW:mobilepsw
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
By default, if the initial attempt to transmit data to the monitoring station via GPRS network method is unsuccessful, the system will make
up to 2 additional attempts. If all attempts are unsuccessful, the system will switch to next backup connection that follows in the sequence
and will attempt to transmit data until it is successfully delivered to the monitoring station.
Set attempts
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → MS SETTINGS → OK → GPRS SETTINGS → OK
→ GPRS ATTEMPTS → OK → att → OK
Value: aaaa – 4-digit administrator password; att – number of attempts, range – [1... 255].
EKB3
Enter parameter 68 & number of attempts:
68 att #
Value: att – number of attempts, range – [01... 255].
Example: 6809#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
To report the online status, the system periodically transmits (By default – every 180 seconds) Test Event data message (ping) to the
monitoring station via GPRS network.