18
18 EN
MANUAL ELDES ESIM264 V3.1
2.3.7. RS485
Serial Wiring Method
ESIM264
a
b c
d
e
EKB2/EKB3 EKB2/EKB3
EKB2/EKB3
EKB2/EKB3
EPGM1
Max. cable length: a+b+c+d+e = up to 100 meters
NOTE: If necessary, the RS485 devices can be powered from an external 12-14V DC power supply instead of AUX+ and AUX- terminals
ATTENTION: The cable length must not exceed 100 meters in total.
ATTENTION: When wiring more than 1 keypad, please ensure that the set address of each keypad is dierent.
NOTE: You may connect only 1 EKB2/EKB3 keypad or a mixed combination of EKB2 and EKB3 keypads. The combination can consist of
up to 4 keypads in total.
For more details on RS485 device installation, please refer to 32.1. RS485 Interface