Manual ElDES ESIM264 v2.2 17
Parallel Wiring Method
Fig. No. 9
ATTENTION: The cable between ESIM264 and each RS485 device must be of the same length and can NOT exceed 100 meters.
ATTENTION: When wiring more than 1 keyboard, please, make sure that the set address of each keyboard is dierent.
NOTE: You may connect only 1 EKB2/EKB3 keyboard or a mixed combination of EKB2 and EKB3 keyboards. The combination
can consist of up to 4 keyboards in total.
For more details, please, refer to chapters 7.1 EKB2 - LCD Keyboard, 7.2 EKB3 - LED Keyboard, 7.3 EPGM1 - Zone & PGM Output
Expansion Module
ESIM264
EKB2/EKB3 EKB2/EKB3 EKB2/EKB3 EKB2/EKB3
Max. cable length: up to 100 meters