Eldes ESIM264 Installationshandbuch Seite 129

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 140
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 128
Manual ElDES ESIM264 v2.2 129
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET COMMUNICATION
CONNECTION TYPE GPRS / VOICE CALLS / RS485 / CSD / N/A
EKB3
Enter parameter 48 & connection method index:
[480#] - GPRS Network
[481#] - Voice Calls
[482#] - RS485
[483#] - CSD
[484#] - N/A
Primary connection for data transmission from the alarm system to monitoring sta tion. Avai-
lable communication methods: GPRS Network, Voice Calls (GSM audio channel), RS485, CSD.
By default the primary connection is GPRS Network.
Set Primary
Connection
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET CONNECTION TYPE1
GPRS / VOICE CALLS / RS485 / CSD / N/A
OK CONFIGURATION ARC SET CONNECTION TYPE2
GPRS / VOICE CALLS / RS485 / CSD / N/A
OK CONFIGURATION ARC SET CONNECTION TYPE3
GPRS / VOICE CALLS / RS485 / CSD / N/A
EKB3
Enter parameter 83, backup communication entry number & communi-
cation method index:
[83xx0#] - GPRS Network
[83xx1#] - Voice Calls
[83xx2#] - RS485
[83xx3#] - CSD
[83xx4#] - N/A
Value: xx - backup communication entry number, range - [01... 03]
This command sets the sequence order of backup connections in case of primary connection
failure. There can be up to 3 backup connections set in any sequence order.
Set Backup
Connection (-s)
Seitenansicht 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 139 140

Kommentare zu diesen Handbüchern