Eldes ESIM264 Installationshandbuch Seite 135

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 140
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 134
Manual ElDES ESIM264 v2.2 135
9.3.3 Voice Calls Settings
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET
ARC STATION NUM TEL. NUMBER [1... 3] [XXXXXXXXXXXXXXX]
Value: [XXXXXXXXXXXXXXX] – up to 15 digits phone number
EKB3
Enter parameter 26, number of phone number entry & phone number
[26xxyyyyyyyyyyyyyyy#]
Value: xx – number of monitoring station phone number entry, range – [01...
03]; yyyyyyyyyyyyyyy – up to 15 digits phone number
The system supports up to 3 monitoring station phone numbers for communication with
the alarm system by Voice Calls (GSM audio channel) method. Tel. Number 1 is mandatory, the
other two are not necessary. All numbers must be entered starting with international country
code e.g. 44[area code][local number]. The plus character is not necessary.
Set Monitoring Station
Phone Number
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET COMMUNICATION TEST PERIOD [XXXXX]
Value: [XXXXX] – test time period in seconds, range - [0... 65535]
EKB3
Enter parameter 46 & test time period:
[46xxxxx#]
Value: xxxxx – test time period in seconds, range - [0... 65535]
Time period of test data message sending to monitoring station via GPRS network. This mes-
sage is intended for alarm system status checking. Default value is 180 seconds.
Set Test Period