2.6 Managing Cx Controller. Timer
Alarm system ESIM264 has 4 open-collector controlled outputs C1, C2, C3 and C4. They can be used to control various electrical
devices such as electric pumps, heating, lighting, etc. When outputs are enabled, it corresponds to output pins being pulled to
ground (GND).
Enabling output:
Disabling output:
Set controlled output names can be used instead of C1,C2, C3 or C4.
Timer
Alarm system ESIM264 has internal timer clock. This feature allows any controlled output to be switched
on or o for a specied time period. The following SMS command should be sent:
ON – output enabled. OFF – disabled; vv – hours, valid values [00-24] mm – minutes, valid values
[00-60] ss - seconds, valid values [00-60]. It is not allowed to have all values equal zeros.
2.7 External power supply control
The system ESIM264 will report every time mains 230V power supply fails or recovers. In some remote places where mains power
supply is unreliable, the system can be congured to ignore these changes. Send SMS:
Or it can be enabled by SMS message:
2.8 INFO on Status indication SMS messages (signal strength, status, temperature)
Security system ESIM264 can be inquired at any time about its status, signal strength, zone status. At the same time system can be
tested. If SMS response message is received, means system is functioning properly. This is also useful for users with prepaid SIM
cards. It can be checked whether SIM card has enough remaining balance for sending SMS. Send SMS message:
The response SMS message will be received, e.g.2009.01.07 11:15 System armed/disarmed Signal Strength Fair. External power
supply OK. Temperature 20oC. Z1:OK/ALARM Z2:OK/ALARM Z3:OK/ALARM Z4:OK/ALARM Z5:OK/ALARM Z6:OK/ALARM
Where OK – if zone has not been activated, ALARM – if been activated
By default, this status SMS message will be sent daily at 11:00 in the morning.
These parameters can be congured with SMS message:
PP – message period in days, valid values [00 – 10]; VV - time when message is sent, valid values [00 –
23] If PP value is 0, and VV in the range of [1-23], then periodic status messages will be sent multiple
times per day, with period being specied as VV time.
XXXX_C1:ON
XXXX_C1:OFF
XXXX_M:OFF
XXXX_M:ON
XXXX_INFO
XXXX_INFO:PP.VV
XXXX_C1:ON/OFF:VV.MM.SS
ESIM 264
1111 C2:
ON
ESIM 264
1111 C1:
ON:00.01.
23
ESIM 264
1111 M:
OFF
ESIM 264
1111 INFO
:0.2