1. General information
1.1 About User Manual
This document describes alarm security system ESIM264 operation. It is very important to read User Manual before start using
the system.
1.2 Ways to arm the system
Arming system by phone
To arm the system by phone user has to call to the number of the SIM card inserted in ESIM264 device. When alarm system number
has been dialed and ringing is dropped after three call signals – means the system was successfully armed. When system is armed
via phone call, there is no time delay; the alarm system is activated immediately. Users have to use this way of arming when they
already left the secured premises.
Arming system by keyboard
To arm the system by keyboard, user have to enter password on the keyboard. The security alarm system will not get armed if any
of the zones is active. If wrong password is entered, the keyboard beeps and user have to enter password again. When the pass-
word is entered, the system buzzer and/or LED will inform that delay time has started. Manufacturer by default set 15 sec. delay
time to leave the premises. If the user will not leave the premises in delay time, the system will start an alarm.
Arming system by iButton
To arm the system with iButton, user have to insert iButton into the reader. The security alarm system will not get armed if any
of the zones is active. When the iButton is inserted into the reader, the system buzzer and/or LED will inform that delay time has
started. Manufacturer by default set 15 sec. delay time to leave the premises. If the user will not leave the premises in delay time,
the system will start an alarm.
1.3 Ways to disarm the system
Disarming system by phone
To disarm the system by phone user has to call to the number of the SIM card inserted in ESIM264 device. When alarm system
number has been dialed and ringing is dropped after one call signal – means the system was successfully disarmed.
Disarming system by keyboard
To disarm the system by keyboard, user have to come in to the secured premises and enter password on the keyboard. When user
enters in to security premises, delay zones are violated and system buzzer and/or LED is informing that entry delay time has star-
ted. Manufacturer by default set 15 sec. delay time to enter the password. If wrong password is entered, the keyboard beeps and
user have to enter password again. If the user will not enter the correct password in entry time, the system will start an alarm. This
parameter can be individually adjusted for any Delay zone by installer.
Disarming system by iButton
To disarm the system by iButton, user have to enter to the secured premises and insert iButton into the reader. When user enters in
to security premises, delay zones are violated and system buzzer and/or LED is informing that entry delay time has started. Manu-
facturer by default set 15 sec. delay time to insert iButton into the reader . If the user will not insert iButton into the reader in entry
time, the system will start an alarm. This parameter can be individually adjusted for any Delay zone by installer.